Clear-span industrial steel structures
Every envelope component is calculated for dead loads, live loads, and collateral dead loads imposed by utility solar installations.
Primary Built-Up Frames
Secondary Cold-Formed Members
Cladding & Solar Profiles
Variable cross-section tapered I-beams fabricated from 345 MPa high-tensile steel plates using automated continuous submerged arc welding lines to maximize load capacity while trimming dead weight.
Continuous nested Z and C purlins roll-formed from pre-galvanized 275 GSM steel coils, providing rigid structural backing for wall girts and roof envelopes under maximum uplift pressures.
High-rib standing seam roof sheets and insulated polyurethane core panels engineered with non-penetrating clamping profiles, rated for Category 4 wind suction and heavy module racking.
Engineered to IS 800 standards and calculated for 50 m/s wind speeds
Structural calculations account for peak gust velocities, crane operational surge forces, and seismic zone 4 displacement criteria across all Indian industrial corridors.
Millimeter tolerance from shop to site
Tekla 3D Detailing
Automated Shop Fabrication
Surface Preparation & Coating
Erection & Torque Audits
Full structural modeling generates clash-free CNC shop drawings, connection node coordinates, and detailed anchor bolt setting layouts.
CNC plasma multi-torch cutting, robotic beam fit-up, and automated twin-wire submerged arc welding ensure consistent penetration across heavy plate thicknesses.
Centrifugal wheel shot blasting to SA 2.5 profile standards followed by high-build epoxy zinc-phosphate primers for aggressive industrial atmospheres.
Rigid site crane rigging overseen by certified structural engineers, concluding with calibrated torque wrench verification on all high-strength friction grip bolts.
Send architectural parameters, column grid layouts, or structural tender documents directly to our engineering desk in Kanpur.